aileike@outlook.com +86 18915184475
ENEN PTPT IDID RURU ARAR
Facebook
X
Youtube
TIKTOK
TELEGRAM
AILEIKE TT&C EQUIPMENT(HUAIAN)CO., LTD.
ENEN PTPT IDID RURU ARAR
  • Home
  • About us
  • Products
    • Pressure series
      • ELECTRODYNAMIC calibration series
      • Pointer pressure gauge
      • Air pressure calibration
      • Hydraulic Calibration
      • Handheld series
      • pressure calibrator
      • Pressure conversion connector
      • Pressure transmitter
    • Digtal pressure gauge
    • Calibration series
      • Temperature calibration
      • 475
    • Liquid level series
      • Radar level gauge
      • Level gauge
      • guided wave radar
      • Tuning fork/RF admittance
      • Magnetic level gauge
    • Temperature series
      • Thermal resistance
      • Bimetal thermometer
      • Thermocouple
    • Flow series
      • Electromagnetic flowmeter
      • Turbine flowmeter
      • Vortex flowmeter
      • Flow meter
      • Ultrasonic flowmeter
    • Petroleum Machinery
    • Display series
      • Digital display series
      • Recording instrument
    • Accessory
  • News
    • Technical articles
    • Industry-news
  • F.A.Q
  • Contact us
Get a Quote
Quick Inquiry

Get a Quote

Fill in the form below and we will get back to you shortly.

  1. Home
  2. Products
  3. Temperature series
  4. Thermocouple
  5. Platinum rhodium thermocouple WRR-120

Platinum rhodium thermocouple WRR-120

Share
Facebook
X
Youtube
TIKTOK
TELEGRAM
Inquiry Send Email

Description

Overviews

latinum rhodium thermocouple WRR-120 industrial assembled thermocouple is used as a temperature sensor, which is usually used with display instrument, recording instrument and electronic regulator. It can directly measure the surface temperature of liquid, steam and gas medium in the range of 0 ℃ to 1800 ℃ in various production processes.

Specification

Warranty
1years
Place of Origin
China
Jiangsu
Brand Name
AILEIKE
Size:
custom

Temperature measurement range and allowable error

Thermocouple category

Code name

Dividing number

Measuring range ℃

Allowable deviation t ℃

Platinum and rhodium30-Platinum and Rhodium6

WRR

B

01800

±1.5 ℃ or ±0.25%

Platinum rhodium 10-platinum

WRP

S

0 ≤ 1600

±1.5 ℃ or ±0.25%

Nickel-chromium-nickel-silicon

WRN

K

0 / 1300

±2.5 ℃ or ±0.75%

Nickel chromium copper nickel

WRE

E

0 / 800

±2.5 ℃ or ±0.75%

Model selection:

Unfixed type (ceramic protective tube) thermocouple

Thermocouple category

Product model

Dividing number

Temperature range ℃

Specifications

Thermal response time T0.5 S

Diameter mm

Protective pipe material

Single platinum and rhodium30-Platinum and Rhodium6

WRR-120

B

0~1600

16

Corundum quality

< 150

WRR-121

25

< 360

Double platinum rhodium30-Platinum and Rhodium6

WRR2-120

16

< 150

WRR2-121

25

< 360

Single platinum and rhodium10-Platinum

WRP-120

S

0~1300

16

High aluminum content

< 150

WRP-121

25

< 360

Double platinum rhodium10-Platinum

WRP2-120

16

< 150

WRP2-121

25

< 360

Single Ni-Cr-Ni-Si

WRN-122

K

0~1100

16

High aluminum content

< 240

WRN-123

0~1200

20

Double branch nickel-chromium-nickel-silicon

WRN2-123

0~1100

Single platinum and rhodium30-Platinum and Rhodium6

WRR-130

B

0~1600

16

Corundum quality

< 150

< 360

< 150

WRR-131

25

< 360

Double platinum rhodium30-Platinum and Rhodium6

WRR2-130

16

WRR2-131

25

Single platinum and rhodium10-Platinum

WRP-130

S

0~1300

16

High aluminum content

< 150

< 360

< 150

WRP-131

25

< 360

Double platinum rhodium10-Platinum

WRP2-130

16

WRP2-131

25

Single Ni-Cr-Ni-Si

WRN-133

K

0~1200

20

High aluminum content

< 240

Double branch nickel-chromium-nickel-silicon

WRN2-133

0~1100

Note:1) structural characteristics: the non-inserted part is carbon steel 20 #

2)Diameter, diameter.25mm is a double-layer porcelain casing.


Working principle of thermocouple

Two stages of conductors with different components are welded to form a loop. The direct temperature measuring end is called the measuring end, and the terminal terminal is called the reference terminal. When there is a temperature difference between the measuring end and the reference end, the thermal current will be generated in the loop, which will be connected to the display instrument, and the corresponding temperature value of the thermoelectric force produced by the thermocouple will be indicated on the instrument.




Inquiry Us





Related Products

Diaphragm pressure gauge yb-100rlmf

Diaphragm pressure gauge yb-100rlmf

Industrial Temperature Sensor thermocouple WRN-243

Industrial Temperature Sensor thermocouple WRN-243

Hydraulic calibration table ALKT9803 0~600bar

Hydraulic calibration table ALKT9803 0~600bar

Portable micro-pressure pump ALKB202

Portable micro-pressure pump ALKB202

Automatic pressure calibration table ALKD91B 0~600bar

Automatic pressure calibration table ALKD91B 0~600bar

Diaphragm pressure gauge yb-100gymc

Diaphragm pressure gauge yb-100gymc

Product Categories

  • Pressure series
    • ELECTRODYNAMIC calibration series
    • Pointer pressure gauge
    • Air pressure calibration
    • Hydraulic Calibration
    • Handheld series
    • pressure calibrator
    • Pressure conversion connector
    • Pressure transmitter
  • Digtal pressure gauge
  • Calibration series
    • Temperature calibration
    • 475
  • Liquid level series
    • Radar level gauge
    • guided wave radar
    • Level gauge
    • Tuning fork/RF admittance
    • Magnetic level gauge
  • Temperature series
    • Thermal resistance
    • Bimetal thermometer
    • Thermocouple
  • Flow series
    • Electromagnetic flowmeter
    • Turbine flowmeter
    • Vortex flowmeter
    • Flow meter
    • Ultrasonic flowmeter
  • Petroleum Machinery
  • Display series
    • Digital display series
    • Recording instrument
  • Accessory

Links

Google.comBaidu.com

侧边1

侧边2

Latest Post

  • Recommended Pressure Standards - ALKB9601
    Recommended Pressure Standards - ALKB960
    2026-06-12
  • Recommended Pressure Standards - ALKB202
    Recommended Pressure Standards - ALKB202
    2026-06-11
  • Recommended Pressure Standards - ALKB201
    Recommended Pressure Standards - ALKB201
    2026-06-10

Feedback

Contact Us

3841141734

+86 18915184475

+86-18915184475

aileike@outlook.com

No. 6, Yinjizhen Industrial Park, Jiangsu Province

Mobile Website

Mobile QR Code


Copyright © 2013-2020 AILEIKE TT&C EQUIPMENT(HUAIAN)CO., LTD. All Rights Reserved.

https://www.youtube.com/@aileike https://x.com/AiLeike1201 https://vk.ru/id1085515017 https://www.youtube.com/@aileike https://www.tiktok.com/@aileike01 +86 18915184475 aileike@outlook.com +86-18915184475
WeChat
WeChat QR Code