+86-0517-86992080 aileike@outlook.com

Facebook
Twitter
Youtube
LinkedIn
Pinterest

AILEIKE TT&C EQUIPMENT(HUAIAN)CO., LTD.
  • Home
  • About us
  • Products
    • Pressure series
      • ELECTRODYNAMIC calibration series
      • Pointer pressure gauge
      • Air pressure calibration
      • Hydraulic Calibration
      • Handheld series
      • pressure calibrator
      • Pressure conversion connector
      • Pressure transmitter
    • Digtal pressure gauge
    • Calibration seres
      • Temperature calibration
      • 475
    • Liquid level series
      • Radar level gauge
      • Level gauge
      • guided wave radar
      • Tuning fork/RF admittance
      • Magnetic level gauge
    • Temperature series
      • Thermal resistance
      • Bimetal thermometer
      • Thermocouple
    • Flow series
      • Electromagnetic flowmeter
      • Turbine flowmeter
      • Vortex flowmeter
      • Flow meter
      • Ultrasonic flowmeter
    • Petroleum Machinery
    • Display series
      • Digital display series
      • Recording instrument
    • Accessory
    • Valve
  • News
    • Technical articles
    • Industry-news
  • F.A.Q
  • Feedback
  • Contact us
  1. Home
  2. Products
  3. Temperature series
  4. Thermocouple
  5. Platinum rhodium thermocouple WRR-120

Platinum rhodium thermocouple WRR-120

Inquiry Send Email

Description

Overviews

latinum rhodium thermocouple WRR-120 industrial assembled thermocouple is used as a temperature sensor, which is usually used with display instrument, recording instrument and electronic regulator. It can directly measure the surface temperature of liquid, steam and gas medium in the range of 0 ℃ to 1800 ℃ in various production processes.

Specification

Warranty
1years
Place of Origin
China
Jiangsu
Brand Name
AILEIKE
Size:
custom

Temperature measurement range and allowable error

Thermocouple category

Code name

Dividing number

Measuring range ℃

Allowable deviation t ℃

Platinum and rhodium30-Platinum and Rhodium6

WRR

B

01800

±1.5 ℃ or ±0.25%

Platinum rhodium 10-platinum

WRP

S

0 ≤ 1600

±1.5 ℃ or ±0.25%

Nickel-chromium-nickel-silicon

WRN

K

0 / 1300

±2.5 ℃ or ±0.75%

Nickel chromium copper nickel

WRE

E

0 / 800

±2.5 ℃ or ±0.75%

Model selection:

Unfixed type (ceramic protective tube) thermocouple

Thermocouple category

Product model

Dividing number

Temperature range ℃

Specifications

Thermal response time T0.5 S

Diameter mm

Protective pipe material

Single platinum and rhodium30-Platinum and Rhodium6

WRR-120

B

0~1600

16

Corundum quality

< 150

WRR-121

25

< 360

Double platinum rhodium30-Platinum and Rhodium6

WRR2-120

16

< 150

WRR2-121

25

< 360

Single platinum and rhodium10-Platinum

WRP-120

S

0~1300

16

High aluminum content

< 150

WRP-121

25

< 360

Double platinum rhodium10-Platinum

WRP2-120

16

< 150

WRP2-121

25

< 360

Single Ni-Cr-Ni-Si

WRN-122

K

0~1100

16

High aluminum content

< 240

WRN-123

0~1200

20

Double branch nickel-chromium-nickel-silicon

WRN2-123

0~1100

Single platinum and rhodium30-Platinum and Rhodium6

WRR-130

B

0~1600

16

Corundum quality

< 150

< 360

< 150

WRR-131

25

< 360

Double platinum rhodium30-Platinum and Rhodium6

WRR2-130

16

WRR2-131

25

Single platinum and rhodium10-Platinum

WRP-130

S

0~1300

16

High aluminum content

< 150

< 360

< 150

WRP-131

25

< 360

Double platinum rhodium10-Platinum

WRP2-130

16

WRP2-131

25

Single Ni-Cr-Ni-Si

WRN-133

K

0~1200

20

High aluminum content

< 240

Double branch nickel-chromium-nickel-silicon

WRN2-133

0~1100

Note:1) structural characteristics: the non-inserted part is carbon steel 20 #

2)Diameter, diameter.25mm is a double-layer porcelain casing.


Working principle of thermocouple

Two stages of conductors with different components are welded to form a loop. The direct temperature measuring end is called the measuring end, and the terminal terminal is called the reference terminal. When there is a temperature difference between the measuring end and the reference end, the thermal current will be generated in the loop, which will be connected to the display instrument, and the corresponding temperature value of the thermoelectric force produced by the thermocouple will be indicated on the instrument.




Inquiry Us





Related Products

Lwgyc-15 turbine flowmeter

Lwgyc-15 turbine flowmeter

Turn the level switch alkzx-d2.

Turn the level switch alkzx-d2.

Industrial Temperature Sensor thermocouple WRN2-242

Industrial Temperature Sensor thermocouple WRN2-242

High precision digital display temperature control recording instrument Intelligent digital display instrument

High precision digital display temperature control recording instrument Intelligent digital display instrument

Industrial Temperature Sensor thermocouple WRN-130

Industrial Temperature Sensor thermocouple WRN-130

Industrial Temperature Sensor thermocouple WRN-722

Industrial Temperature Sensor thermocouple WRN-722

Product Categories

  • Pressure series
    • ELECTRODYNAMIC calibration series
    • Pointer pressure gauge
    • Air pressure calibration
    • Hydraulic Calibration
    • Handheld series
    • pressure calibrator
    • Pressure conversion connector
    • Pressure transmitter
  • Digtal pressure gauge
  • Calibration seres
    • Temperature calibration
    • 475
  • Liquid level series
    • Radar level gauge
    • guided wave radar
    • Level gauge
    • Tuning fork/RF admittance
    • Magnetic level gauge
  • Temperature series
    • Thermal resistance
    • Bimetal thermometer
    • Thermocouple
  • Flow series
    • Electromagnetic flowmeter
    • Turbine flowmeter
    • Vortex flowmeter
    • Flow meter
    • Ultrasonic flowmeter
  • Petroleum Machinery
  • Display series
    • Digital display series
    • Recording instrument
  • Accessory
  • Valve

Links

Google.comBaidu.com

内页左侧广告1

内页左侧广告2

LatestPost

  • Explanation of working principle of thermocouple
    Explanation of working principle of ther
    2021-04-08
  • Installation requirements for turbine flow meters
    Installation requirements for turbine fl
    2021-04-02
  • The working principle and advantages of magnetic flapper level gauge
    The working principle and advantages of
    2021-03-31

Feedback

Contact Us

1779520269

+8618915184475

+86-0517-86992080

aileike@outlook.com

No. 6, Fuqiang Road, Yinji, Jinhu County, Jiangsu Province

MOBILE WEBSITE

Copyright © 2013-2020 AILEIKE TT&C EQUIPMENT(HUAIAN)CO., LTD. All Rights Reserved.

  • Skype.
  • E-mail
  • Whatsapp
  • Inquiry