aileike@outlook.com +86 18915184475
ENEN PTPT IDID RURU ARAR
Facebook
X
Youtube
TIKTOK
TELEGRAM
AILEIKE TT&C EQUIPMENT(HUAIAN)CO., LTD.
ENEN PTPT IDID RURU ARAR
  • Home
  • About us
  • Products
    • Pressure series
      • ELECTRODYNAMIC calibration series
      • Pointer pressure gauge
      • Air pressure calibration
      • Hydraulic Calibration
      • Handheld series
      • pressure calibrator
      • Pressure conversion connector
      • Pressure transmitter
    • Digtal pressure gauge
    • Calibration series
      • Temperature calibration
      • 475
    • Liquid level series
      • Radar level gauge
      • Level gauge
      • guided wave radar
      • Tuning fork/RF admittance
      • Magnetic level gauge
    • Temperature series
      • Thermal resistance
      • Bimetal thermometer
      • Thermocouple
    • Flow series
      • Electromagnetic flowmeter
      • Turbine flowmeter
      • Vortex flowmeter
      • Flow meter
      • Ultrasonic flowmeter
    • Petroleum Machinery
    • Display series
      • Digital display series
      • Recording instrument
    • Accessory
  • News
    • Technical articles
    • Industry-news
  • F.A.Q
  • Contact us
Get a Quote
Quick Inquiry

Get a Quote

Fill in the form below and we will get back to you shortly.

Technical articles

  1. Home
  2. News
  3. Technical articles
  4. Operating Instructions and Application S...

Operating Instructions and Application Scenarios for the AILEIKE ALKT702 Air Pressure Calibration Bench

The AILEIKE ALKT702 air pressure calibration bench is a manual air pressure calibration device that can achieve stable output of positive and negative pressure by manual pressure application. It is widely used in various scenarios such as laboratory verification, industrial field calibration, and instrument quality inspection. This article will comprehensively introduce the technical parameters, operation process, application scenarios, and usage precautions of this device, providing a reference for standardizing equipment usage and ensuring calibration quality.

1. Technical indicators

name

Air pressure calibration bench

Pressurization method

manual

model

ALKT702

medium

clean air

pressure range

-0.095~6MPa

Overall dimensions

400×320×185mm

Adjust fineness

10 Pa

weight

10kg

Output port

2 pieces

Pressure connection

Quick-connect thread (M20*1.5)

Ambient temperature

-10~60℃

material

Stainless steel

II. Operating Methods

First, place the pressure calibration bench on a flat workbench, ensuring that the site is free from vibration, dust, and corrosive gases. Connect the standard gauge and the verified pressure gauge in a sealed manner to the ALKT702 output port.

1. Positive pressure verification process

(1) Voltage boosting process

First, open the pressure regulating valve of ALKT702, then push the positive and negative pressure switching valve inwards (do not switch under pressure), and adjust the micro-adjustment knob counterclockwise until it cannot be adjusted further, then close the pressure relief valve.

When operating the lever to increase the pressure to 3~4MPa, close the pressure regulating valve, use the fine adjustment to adjust the pressure to around 6MPa, stabilize it for 1~2 minutes, and then use the fine adjustment to adjust it to the verification point.

(2) Decompression process

First, slowly open the pressure relief valve and reduce the pressure until it stops at the verification point. Then, close the pressure relief valve and use the fine adjustment valve to slowly adjust it counterclockwise/clockwise to the verification point.

(3) Pressure relief process

Open the pressure relief valve and the pressure regulating valve in sequence, gradually releasing the pressure inside the pipeline until it reaches 0. The measurement is complete.

2. Negative pressure verification process

(1) Voltage boosting process

Pull out the positive and negative pressure switching valve (do not switch under pressure), then open the pressure regulating valve, and turn the ALKT702 fine adjustment knob clockwise until it stops, then close the pressure relief valve.

• Use the hand-operated pressure rod to evacuate the vacuum until it reaches approximately the verification value, then use the fine adjustment to slowly turn counterclockwise to reach the verification point.

(2) Decompression process

First, slowly open the pressure relief valve to reduce the pressure to around the verification value and then stop. Close the pressure relief valve and use the fine adjustment valve to slowly adjust clockwise/counterclockwise to the verification point.

(3) Pressure relief process

Open the pressure relief valve, gradually release the pressure in the pipeline, and when the pressure relief reaches 0, the measurement is complete.

III. Application Scenarios

1. Metrological testing site

Metrology institutes at all levels, third-party testing facilities, and other venues are utilized for the periodic verification and accuracy calibration of various pressure instruments, issuing compliant calibration data to ensure the compliant use of measuring instruments.

2. Industrial production operation and maintenance

In industries such as electricity, chemical, pharmaceutical, HVAC, and metallurgy, it is advisable to regularly calibrate in-service pressure instruments on production lines, promptly correct data deviations, avoid production failures and risks, and ensure stable operation of the production line.

3. Quality inspection of instrument production

Pressure instrument manufacturers can utilize these tools for product debugging, accuracy testing, and final quality inspection, screening out non-compliant products, and ensuring that the accuracy of the instruments leaving the factory meets the required standards.

4. Teaching and scientific research experiments

Universities and research institutes can utilize this equipment as experimental teaching tools for stress-related practical teaching and basic scientific research experiments. The equipment is easy to operate, provides stable data, and is well-suited for teaching scenarios.

IV. Precautions

1. The calibration table should be placed on a flat and easily accessible surface. The instrument being tested should be wiped properly to prevent stains from entering the detection circuit.

2. When the leverage pressure is heavy, please use fine adjustment to increase the pressure, which will make it easier.

3. During operation, please ensure that you do not switch between positive and negative pressure while under pressure. Instead, fully depressurize before operating the switching valve.

4. It is strictly prohibited to disassemble instruments and pipelines when the equipment is under pressure. Operation must be carried out after the pressure is completely released and reset to zero, to prevent accidents caused by high-pressure gas ejection.

5. Regularly clean the interface debris, inspect and replace aging sealing gaskets to prevent air leakage issues.

6. When the equipment is not in use for a long period, ensure that all valves are loosened, pressure is reset to zero, and interfaces are sealed to prevent dust. Store the equipment in a dry, dust-free, and non-corrosive environment.

V. Conclusion

In summary, the AILEIKE Bench ALKT702 from AILEIKE boasts an exquisite structure, stable performance, and simple operation, meeting the needs of laboratory calibration and industrial field operations. It effectively addresses the issues of cumbersome operation and limited scenarios associated with traditional air pressure calibration equipment. This device is capable of completing the verification, calibration, debugging, and quality inspection of various air pressure instruments, providing solid technical support for the stable operation in fields such as industrial production, metrological testing, scientific research, and teaching.

Related News

Steps for using and calibration application areas of the AILEIKE ALKB202 portable micro-pressure pump

Steps for using and calibration application areas of the AIL

Standardised Operating Procedures for the Calibration, Testing and Maintenance of Type K Thermocouples

Standardised Operating Procedures for the Calibration, Testi

Operation method and application scenarios of the AILEIKE ALKT9801 hydraulic calibration bench

Operation method and application scenarios of the AILEIKE AL

Operation explanation of AILEIKE portable air pump ALKB602, pressure gauge calibration is no longer a hassle

Operation explanation of AILEIKE portable air pump ALKB602,

End-to-End Calibration of Pressure Switches: Standardised Operational Procedures Based on the AILEIKE ALKT803 and ALKC400T

End-to-End Calibration of Pressure Switches: Standardised Op

AILEIKE Pressure Transmitter Calibration (HART Protocol) Standardised Operating Guidelines

AILEIKE Pressure Transmitter Calibration (HART Protocol) Sta

Product Categories

  • Pressure series
    • ELECTRODYNAMIC calibration series
    • Pointer pressure gauge
    • Air pressure calibration
    • Hydraulic Calibration
    • Handheld series
    • pressure calibrator
    • Pressure conversion connector
    • Pressure transmitter
  • Digtal pressure gauge
  • Calibration series
    • Temperature calibration
    • 475
  • Liquid level series
    • Radar level gauge
    • guided wave radar
    • Level gauge
    • Tuning fork/RF admittance
    • Magnetic level gauge
  • Temperature series
    • Thermal resistance
    • Bimetal thermometer
    • Thermocouple
  • Flow series
    • Electromagnetic flowmeter
    • Turbine flowmeter
    • Vortex flowmeter
    • Flow meter
    • Ultrasonic flowmeter
  • Petroleum Machinery
  • Display series
    • Digital display series
    • Recording instrument
  • Accessory

Links

Alibaba.comFacebook.comYoutube.comTiktok.comGoogle.comBaidu.com

侧边1

侧边2

Latest Post

  • Operating Instructions and Application Scenarios for the AILEIKE ALKT702 Air Pressure Calibration Bench
    Operating Instructions and Application S
    2026-10-26
  • Key points for using the AILEIKE ALKT512 fine pressure calibration bench and applicable working conditions for differential pressure
    Key points for using the AILEIKE ALKT512
    2026-10-24
  • Introduction to the usage specifications and scenarios of the AILEIKE ALKT511 micro-pressure calibration bench
    Introduction to the usage specifications
    2026-10-23

Feedback

Contact Us

3841141734

+86 18915184475

+86-18915184475

aileike@outlook.com

No. 6, Yinjizhen Industrial Park, Jiangsu Province

Mobile Website

Mobile QR Code


Copyright © 2013-2020 AILEIKE TT&C EQUIPMENT(HUAIAN)CO., LTD. All Rights Reserved.

https://www.youtube.com/@aileike https://x.com/AiLeike1201 https://vk.ru/id1085515017 https://www.youtube.com/@aileike https://www.tiktok.com/@aileike01 +86 18915184475 aileike@outlook.com +86-18915184475
WeChat
WeChat QR Code