aileike@outlook.com +86 18915184475
ENEN PTPT IDID RURU ARAR
Facebook
X
Youtube
TIKTOK
TELEGRAM
AILEIKE TT&C EQUIPMENT(HUAIAN)CO., LTD.
ENEN PTPT IDID RURU ARAR
  • Home
  • About us
  • Products
    • Pressure series
      • ELECTRODYNAMIC calibration series
      • Pointer pressure gauge
      • Air pressure calibration
      • Hydraulic Calibration
      • Handheld series
      • pressure calibrator
      • Pressure conversion connector
      • Pressure transmitter
    • Digtal pressure gauge
    • Calibration series
      • Temperature calibration
      • 475
    • Liquid level series
      • Radar level gauge
      • Level gauge
      • guided wave radar
      • Tuning fork/RF admittance
      • Magnetic level gauge
    • Temperature series
      • Thermal resistance
      • Bimetal thermometer
      • Thermocouple
    • Flow series
      • Electromagnetic flowmeter
      • Turbine flowmeter
      • Vortex flowmeter
      • Flow meter
      • Ultrasonic flowmeter
    • Petroleum Machinery
    • Display series
      • Digital display series
      • Recording instrument
    • Accessory
  • News
    • Technical articles
    • Industry-news
  • F.A.Q
  • Contact us
Get a Quote
Quick Inquiry

Get a Quote

Fill in the form below and we will get back to you shortly.

Technical articles

  1. Home
  2. News
  3. Technical articles
  4. Pressure instrument metrological calibra...

Pressure instrument metrological calibration: Standard operating procedures and metrological error calibration specifications

Pressure instruments, as crucial measuring devices in industrial production, have their indication accuracy directly impacting the process. To correct indication errors and maintain stable output from the instruments, a comprehensive calibration specification has been developed: utilizing the ALKT702 air pressure calibration bench and ALKC400E digital pressure calibrator to achieve full coverage verification of both positive and negative ranges of pressure gauges. Relying on a constant temperature laboratory environment, segmented uniform pressure increase, stable pressure readings after standing, light tapping for gap elimination, and synchronous retention of original data following standardized procedures, zero point and full-range linear deviations are corrected. Throughout the entire operation, the rate of pressure increase and decrease is strictly controlled, and data is collected only after the pressure has stabilized, ensuring that measurement errors meet verification standards. The procedure follows standardized steps and traceable recording of the entire process, eliminating measurement hazards and supporting stable and precise measurement and control on the production line.

1. Calibration tool for pressure gauge


The entire verification process must strictly adhere to the current metrological technical specifications. The main basis includes: JJG52-2013 "General Pressure Gauges, Pressure Vacuum Gauges, and Vacuum Gauges with Elastic Elements", which is applicable to the initial verification, subsequent verification, and in-service inspection of general pressure gauges, pressure vacuum gauges, and vacuum gauges with elastic elements, covering locally indicating pressure measuring instruments commonly used in industry.

II. Detailed Explanation of Operational Procedures

(I) Preliminary preparations

1. Environmental requirements

The temperature should be controlled at (20±2)℃, with a relative humidity of ≤85%RH, and there should be no condensation. Ensure that the site is free from vibration, dust, and corrosive gases.

2. Tool connection

• Connect the standard gauge ALKC400E and the verified pressure gauge Y-100BF in a sealed manner to the ALKT702 output port.

(II) Pressure gauge calibration process

1. Voltage boosting process

First, open the pressure regulating valve of ALKT702, then push the positive and negative pressure switching valve inwards (do not switch under pressure), adjust the fine adjustment knob counterclockwise until it cannot be adjusted further, and close the pressure relief valve.

• Use a lever to apply pressure, stopping when the pressure reaches around the verification point. Then, use fine adjustment to slowly turn clockwise to reach the verification point of 1 MPa. After the pressure stabilizes and the standard indicated value no longer fluctuates, check the pressure value of the verified pressure gauge. Next, gently tap the side of the verified pressure gauge's casing with your finger (tapping on the glass or hitting hard is strictly prohibited), observe the pointer position, and record the indicated value after the tapping stabilizes. Use the indicated value after tapping as the actual measured verification reading for this pressure point, and calculate the error.

• Then, use the hand pressure lever to apply pressure until it reaches around 1.9 MPa or 2.9 MPa, and then stop. Use the fine adjustment to slowly turn clockwise to adjust to the verification points of 2 MPa and 3 MPa. Once the pressure stabilizes, tap the pressure gauge being verified and record the value.

Before adjusting to the next verification point, first close the stop valve. Then, use fine adjustment to slowly turn clockwise to reach the verification point of 4MPa. Once the pressure stabilizes, tap the pressure gauge being verified and record the value.

• Finally, directly use the fine adjustment to slowly turn clockwise to the verification points of 5MPa and 6MPa. Once the pressure stabilizes, tap the verified pressure gauge and record the value.

2. Decompression process

• First, slowly open the pressure relief valve and reduce the pressure until it stops at the verification point. Close the pressure relief valve, use the fine adjustment valve to slowly adjust counterclockwise to the verification point of 5 MPa. Once the pressure stabilizes, tap the verified pressure gauge and record the value.

• Perform the same operation with the verification points set to 4MPa, 3MPa, 2MPa, and 1MPa, check the pressure values of the verified pressure gauge, tap the verified pressure gauge, and record the indicated value after the tap becomes stable.

3. Pressure relief process

Open the pressure relief valve and the stop valve in sequence, gradually releasing the pressure inside the pipeline until it reaches 0. The measurement is complete.

(III) Vacuum calibration process of pressure gauge

1. Voltage boosting process

First, remove the verified gauge for measuring positive pressure and install the verified gauge for measuring negative pressure. Pull out the positive and negative pressure switch valve (do not switch under pressure). Next, open the pressure regulating valve, then turn the ALKT702 fine adjustment knob clockwise until it stops, and close the pressure relief valve.

• Use the hand pressure lever to evacuate the vacuum until it reaches around the verification value, then use the fine adjustment to slowly adjust it counterclockwise to the verification point of -0.02MPa. Once the pressure stabilizes, tap the verified pressure gauge and record the value.

• Perform the same operation with the verification points adjusted to -0.04MPa, -0.06MPa, -0.08MPa, and -0.095MPa, check the pressure values of the verified pressure gauge, tap the verified pressure gauge, and record the indicated value after it stabilizes.

2. Decompression process

• First, slowly open the pressure relief valve to reduce the pressure to around the verification value and then stop. Close the pressure relief valve, use the fine adjustment valve to slowly adjust clockwise to the verification point of -0.08 MPa. Once the pressure stabilizes, tap the verified pressure gauge and record the value.

• Perform the same operation with the verification points adjusted to -0.06MPa, -0.04MPa, and -0.02MPa, check the pressure values of the verified pressure gauge, tap the verified pressure gauge, and record the indicated value after it stabilizes.

3. Pressure relief process

Open the pressure relief valve, gradually release the pressure inside the pipeline, and when the pressure relief reaches 0, the measurement is complete.

III. Precautions

Standardized use

• During verification, it is important to ensure that the tolerance of the standard meter is less than that of the verified meter, in order to ensure accurate and reliable verification results that meet the requirements of metrological specifications.

• The operation should follow standard procedures. The ALKT702 air pressure calibration bench should be pressurized and depressurized slowly to avoid pressure shock.

• Increase the pressure to the verification point and record the indicated value after the standard gauge value stabilizes. For the verified pressure gauge, tap the gauge case after the pressure stabilizes, and take the indicated value after tapping as the accurate reading to ensure accurate recording.

• After the inspection is completed, slowly release the pressure to zero and ensure there is no residual pressure before removing the inspected instrument.

Maintenance and calibration cycle

• Regularly conduct metrological verification on the digital pressure calibrator ALKC400E (it is recommended to do so once a year) to ensure that the measurement accuracy meets the required standards.

• When the pressure gauge is not in use, the power should be turned off. If it is not used for a long time, it should be charged once every three months.

• If the air pressure table is not used for a long time, it should be depressurized and stored, covered with a cloth cover to prevent dust from entering the instrument.

IV. Conclusion

The periodic verification of pressure gauges has been fully completed. The entire process strictly followed the standard procedures of graded step pressure increase and decrease, pressure stabilization and reading, and repeated verification of forward and reverse strokes. Light tapping on the gauge case was used to eliminate mechanical hysteresis errors. All range verification points were fully collected and calculated, and the accuracy and long-term stability of the instrument readings were verified item by item. The verification operation process was compliant, the original records were complete and valid, and deviations in zero point, linearity, and return stroke were investigated. All measurement parameters met the verification specification requirements.

Related News

A Comprehensive Operational Guide to the Full Process of Accurate Calibration, Testing and Measurement of Pressure Gauges

A Comprehensive Operational Guide to the Full Process of Acc

AILEIKE Blackbody Radiation Source: Calibration of Industrial-Grade Infrared Temperature Measurement Equipment – Heating and Cooling Procedures

AILEIKE Blackbody Radiation Source: Calibration of Industria

Operational Procedures for the Calibration and Testing of Pressure Switches Based on the AILEIKE ALKT9603 and ALKC400E

Operational Procedures for the Calibration and Testing of Pr

Standard specification and calibration procedure for pressure switch (pressure controller)

Standard specification and calibration procedure for pressur

Usage scenarios and operation methods of AILEIKE ALKH512 Thermal Engineering Guide

Usage scenarios and operation methods of AILEIKE ALKH512 The

The difference between a portable air pressure pump and an air pressure calibration station - taking the AILEIKE ALKB602 and ALKT702 as examples

The difference between a portable air pressure pump and an a

Product Categories

  • Pressure series
    • ELECTRODYNAMIC calibration series
    • Pointer pressure gauge
    • Air pressure calibration
    • Hydraulic Calibration
    • Handheld series
    • pressure calibrator
    • Pressure conversion connector
    • Pressure transmitter
  • Digtal pressure gauge
  • Calibration series
    • Temperature calibration
    • 475
  • Liquid level series
    • Radar level gauge
    • guided wave radar
    • Level gauge
    • Tuning fork/RF admittance
    • Magnetic level gauge
  • Temperature series
    • Thermal resistance
    • Bimetal thermometer
    • Thermocouple
  • Flow series
    • Electromagnetic flowmeter
    • Turbine flowmeter
    • Vortex flowmeter
    • Flow meter
    • Ultrasonic flowmeter
  • Petroleum Machinery
  • Display series
    • Digital display series
    • Recording instrument
  • Accessory

Links

Alibaba.comFacebook.comYoutube.comTiktok.comGoogle.comBaidu.com

侧边1

侧边2

Latest Post

  • Pressure instrument metrological calibration: Standard operating procedures and metrological error calibration specifications
    Pressure instrument metrological calibra
    2026-11-17
  • Standard specification and calibration procedure for pressure switch (pressure controller)
    Standard specification and calibration p
    2026-11-16
  • Detailed steps for the calibration, inspection, and metrological operation of stainless steel pressure gauges
    Detailed steps for the calibration, insp
    2026-11-14

Feedback

Contact Us

3841141734

+86 18915184475

+86-18915184475

aileike@outlook.com

No. 6, Yinjizhen Industrial Park, Jiangsu Province

Mobile Website

Mobile QR Code


Copyright © 2013-2020 AILEIKE TT&C EQUIPMENT(HUAIAN)CO., LTD. All Rights Reserved.

https://www.youtube.com/@aileike https://x.com/AiLeike1201 https://vk.ru/id1085515017 https://www.youtube.com/@aileike https://www.tiktok.com/@aileike01 +86 18915184475 aileike@outlook.com +86-18915184475
WeChat
WeChat QR Code