aileike@outlook.com +86 18915184475
ENEN PTPT IDID RURU ARAR
Facebook
X
Youtube
TIKTOK
TELEGRAM
AILEIKE TT&C EQUIPMENT(HUAIAN)CO., LTD.
ENEN PTPT IDID RURU ARAR
  • Home
  • About us
  • Products
    • Pressure series
      • ELECTRODYNAMIC calibration series
      • Pointer pressure gauge
      • Air pressure calibration
      • Hydraulic Calibration
      • Handheld series
      • pressure calibrator
      • Pressure conversion connector
      • Pressure transmitter
    • Digtal pressure gauge
    • Calibration series
      • Temperature calibration
      • 475
    • Liquid level series
      • Radar level gauge
      • Level gauge
      • guided wave radar
      • Tuning fork/RF admittance
      • Magnetic level gauge
    • Temperature series
      • Thermal resistance
      • Bimetal thermometer
      • Thermocouple
    • Flow series
      • Electromagnetic flowmeter
      • Turbine flowmeter
      • Vortex flowmeter
      • Flow meter
      • Ultrasonic flowmeter
    • Petroleum Machinery
    • Display series
      • Digital display series
      • Recording instrument
    • Accessory
  • News
    • Technical articles
    • Industry-news
  • F.A.Q
  • Contact us
Get a Quote
Quick Inquiry

Get a Quote

Fill in the form below and we will get back to you shortly.

Technical articles

  1. Home
  2. News
  3. Technical articles
  4. Based on the full-range operation specif...

Based on the full-range operation specifications for the AILEIKE ALKT703 and ALKC400D check pointer pressure gauge

As an important measuring device for industrial pressure monitoring, the pointer pressure gauge needs to be calibrated regularly according to the metrological technical regulations. This time, we have selected the Aileco ALKT703 pressure calibration bench and ALKC400D precision digital pressure gauge as standard equipment to conduct a full-range verification of the Y-100BF pointer pressure gauge. The calibration includes testing under positive and negative pressure conditions, using a point-by-point pressure increase and decrease verification method. The gauge case is lightly tapped to offset the mechanical hysteresis effect, and the indication error and return error are calculated. Standard instruments are calibrated and maintained on schedule, and the standardized calibration process ensures accurate detection data and meets metrological compliance requirements.

1. Calibration tool for pressure gauge


The entire verification process must strictly adhere to the current metrological technical specifications, primarily based on JJG52-2013 "Elastic Element Type General Pressure Gauges, Pressure Vacuum Gauges, and Vacuum Gauges". This standard is applicable to the initial verification, subsequent verification, and in-service inspection of elastic element type general pressure gauges, pressure vacuum gauges, and vacuum gauges, covering locally indicating pressure measuring instruments commonly used in industry.

II. Detailed Explanation of Operational Procedures

(I) Preliminary preparations

1. Environmental requirements

The temperature should be controlled at (20±2)℃, with a relative humidity of ≤85%RH, and there should be no condensation. Ensure that the site is free from vibration, dust, and corrosive gases.

2. Tool connection

• Connect the standard gauge ALKC400D and the verified pressure gauge Y-100BF to the ALKT703 output port seal, and tighten the other one with a plug.

(II) Pressure gauge calibration process

1. Voltage boosting process

First, open the pressure regulating valve of ALKT703, then push the positive and negative pressure switching valve inward (do not switch under pressure), adjust the fine adjustment knob counterclockwise to the appropriate position, and close the vent valve.

• Apply pressure using a lever, stopping when the pressure reaches the verification point. Then, use fine adjustment to gradually increase the pressure clockwise to 1 MPa at the verification point. Once the pressure stabilizes and the standard indicated value no longer fluctuates, check the pressure value of the verified pressure gauge. Next, gently tap the side of the verified pressure gauge's casing with your finger (do not tap the glass or tap hard), observe the pointer position, and record the indicated value after the tap stabilizes. Use the indicated value after the tap as the actual measured verification reading for this pressure point, and calculate the error.

• Then use the hand pressure lever to apply pressure until it reaches around 1.9 MPa or 2.9 MPa, and then stop. Use the fine adjustment to slowly turn clockwise to adjust to the verification points of 2 MPa and 3 MPa. Once the pressure stabilizes, tap the pressure gauge being verified and record the value.

Before adjusting to the next verification point, first close the stop valve, then use fine adjustment to slowly turn clockwise to reach the verification point of 4MPa. Once the pressure stabilizes, tap the pressure gauge being verified and record the value.

• Finally, directly use the fine adjustment to slowly turn clockwise to the verification points of 5MPa and 6MPa. Once the pressure stabilizes, tap the verified pressure gauge and record the value.

2. Decompression process

• First, slowly open the vent valve and reduce the pressure until it stops at the verification point. Close the vent valve and use the fine adjustment valve to slowly adjust it counterclockwise to 5 MPa at the verification point. Once the pressure stabilizes, tap the verified pressure gauge and record the value.

• Perform the same operation at verification points of 4MPa, 3MPa, 2MPa, and 1MPa, check the pressure values of the verified pressure gauge, tap the verified pressure gauge, and record the indicated value after the tap is stabilized.

3. Pressure relief process

Open the vent valve and the stop valve in sequence, gradually release the pressure inside the pipeline, and when the pressure is released to 0, the measurement is complete.

(III) Pressure gauge vacuum calibration process

1. Voltage boosting process

First, remove the verified gauge for measuring positive pressure and install the verified gauge for measuring negative pressure. Next, open the pressure regulating valve, pull out the positive and negative pressure switch valve (do not switch under pressure), then adjust the ALKT703 micro-adjustment clockwise to the appropriate position, and close the vent valve.

• Use the hand pressure lever to evacuate the vacuum until it reaches the verification value, then use the fine adjustment to slowly adjust it counterclockwise to the verification point of -0.02MPa. Once the pressure stabilizes, tap the verified pressure gauge and record the value.

• Perform the same operation at the verification points of -0.04MPa, -0.06MPa, -0.08MPa, and -0.095MPa, check the pressure values of the verified pressure gauge, tap the verified pressure gauge, and record the indicated value after it stabilizes.

2. Decompression process

• First, slowly open the vent valve to reduce the pressure to around the verification value and then stop. Close the vent valve, use the fine adjustment valve to slowly adjust clockwise to the verification point of -0.08 MPa. Once the pressure stabilizes, tap the verified pressure gauge and record the value.

• Perform the same operation at the verification points of -0.06MPa, -0.04MPa, and -0.02MPa, check the pressure values of the verified pressure gauge, tap the verified pressure gauge, and record the indicated value after the tap is stabilized.

3. Pressure relief process

Open the vent valve, gradually release the pressure inside the pipeline until it reaches 0, and then the measurement is complete.

III. Precautions

Standardized use

• During verification, it is important to ensure that the tolerance of the standard instrument is less than that of the instrument being verified, in order to ensure accurate and reliable verification results that meet the requirements of metrological specifications.

• The operation should follow standard procedures. The ALKT703 air pressure calibration station should be pressurized and depressurized slowly to avoid pressure shock.

• Increase the pressure to the verification point and record the indicated value after the value on the standard gauge stabilizes. After the pressure on the verified pressure gauge stabilizes, gently tap the gauge case, and take the indicated value after tapping as the accurate reading to ensure accurate recording.

• After the inspection is completed, slowly release the pressure to zero and ensure there is no residual pressure before removing the instrument being inspected.

Maintenance and calibration cycle

• Regularly conduct metrological verification on the Precision digital pressure gauge alkc400D (it is recommended to do so once a year) to ensure that the measurement accuracy meets the standard.

• When the pressure gauge is not in use, the power should be turned off. If it is not used for a long time, it should be charged once every three months.

• If the air pressure table is not used for a long time, it should be depressurized and stored, covered with a cloth cover to prevent dust from entering the instrument.

IV. Conclusion

Periodic metrological testing of pressure gauges is fundamental to ensuring reliable operation of industrial pressure monitoring. This time, we completed full-range positive and negative pressure condition testing, standardized the implementation of segmented pressure rise and fall control, stable pressure maintenance, and stable readings, reducing issues such as transient pressure shocks and reading errors. We also maintained supporting standardized pressure equipment and standard instruments, and continuously standardized instrument calibration work. We adhere to regular metrological testing to ensure the authenticity and accuracy of pressure measurement data, avoid instrument inaccuracies, and provide reliable metrological support for compliant operations.

Related News

How to Calibrate Pressure Transmitters (HART Protocol): Metrological Calibration and Standardisation Procedures for the 0–100 MPa High-Pressure Range

How to Calibrate Pressure Transmitters (HART Protocol): Metr

Standardised Calibration Procedures for Pressure Transmitters with a Range of 0–100 MPa (HART Protocol)

Standardised Calibration Procedures for Pressure Transmitter

What equipment is required to calibrate marine pressure gauges on board ships?

What equipment is required to calibrate marine pressure gaug

Introduction to the Operating Specifications and Usage Scenarios of the AILEIKE ALKT803 Hydraulic Calibration Bench

Introduction to the Operating Specifications and Usage Scena

Detailed explanation of the operation method and industry application of the AILEIKE ALKC400D precision digital pressure gauge

Detailed explanation of the operation method and industry ap

Full-range standardised calibration procedures for pressure gauges and practices for accurate measurement — Systematic testing specifications based on the AILEIKE ALKT803 hydraulic calibration bench a

Full-range standardised calibration procedures for pressure

Product Categories

  • Pressure series
    • ELECTRODYNAMIC calibration series
    • Pointer pressure gauge
    • Air pressure calibration
    • Hydraulic Calibration
    • Handheld series
    • pressure calibrator
    • Pressure conversion connector
    • Pressure transmitter
  • Digtal pressure gauge
  • Calibration series
    • Temperature calibration
    • 475
  • Liquid level series
    • Radar level gauge
    • guided wave radar
    • Level gauge
    • Tuning fork/RF admittance
    • Magnetic level gauge
  • Temperature series
    • Thermal resistance
    • Bimetal thermometer
    • Thermocouple
  • Flow series
    • Electromagnetic flowmeter
    • Turbine flowmeter
    • Vortex flowmeter
    • Flow meter
    • Ultrasonic flowmeter
  • Petroleum Machinery
  • Display series
    • Digital display series
    • Recording instrument
  • Accessory

Links

Alibaba.comFacebook.comYoutube.comTiktok.comGoogle.comBaidu.com

侧边1

侧边2

Latest Post

  • Based on the full-range operation specifications for the AILEIKE ALKT703 and ALKC400D check pointer pressure gauge
    Based on the full-range operation specif
    2026-11-27
  • Operation process for pressure gauge calibration, testing, and measurement on the AILEIKE ALKT700 air pressure calibration bench
    Operation process for pressure gauge cal
    2026-11-26
  • Practical Guide for Calibration of AILEIKE 60MPa Dial Pressure Gauge
    Practical Guide for Calibration of AILEI
    2026-11-25

Feedback

Contact Us

3841141734

+86 18915184475

+86-18915184475

aileike@outlook.com

No. 6, Yinjizhen Industrial Park, Jiangsu Province

Mobile Website

Mobile QR Code


Copyright © 2013-2020 AILEIKE TT&C EQUIPMENT(HUAIAN)CO., LTD. All Rights Reserved.

https://www.youtube.com/@aileike https://x.com/AiLeike1201 https://vk.ru/id1085515017 https://www.youtube.com/@aileike https://www.tiktok.com/@aileike01 +86 18915184475 aileike@outlook.com +86-18915184475
WeChat
WeChat QR Code