aileike@outlook.com +86 18915184475
ENEN PTPT IDID RURU ARAR
Facebook
X
Youtube
TIKTOK
TELEGRAM
AILEIKE TT&C EQUIPMENT(HUAIAN)CO., LTD.
ENEN PTPT IDID RURU ARAR
  • Home
  • About us
  • Products
    • Pressure series
      • ELECTRODYNAMIC calibration series
      • Pointer pressure gauge
      • Air pressure calibration
      • Hydraulic Calibration
      • Handheld series
      • pressure calibrator
      • Pressure conversion connector
      • Pressure transmitter
    • Digtal pressure gauge
    • Calibration series
      • Temperature calibration
      • 475
    • Liquid level series
      • Radar level gauge
      • Level gauge
      • guided wave radar
      • Tuning fork/RF admittance
      • Magnetic level gauge
    • Temperature series
      • Thermal resistance
      • Bimetal thermometer
      • Thermocouple
    • Flow series
      • Electromagnetic flowmeter
      • Turbine flowmeter
      • Vortex flowmeter
      • Flow meter
      • Ultrasonic flowmeter
    • Petroleum Machinery
    • Display series
      • Digital display series
      • Recording instrument
    • Accessory
  • News
    • Technical articles
    • Industry-news
  • F.A.Q
  • Contact us
Get a Quote
Quick Inquiry

Get a Quote

Fill in the form below and we will get back to you shortly.

Technical articles

  1. Home
  2. News
  3. Technical articles
  4. Standard Calibration and Testing Operati...

Standard Calibration and Testing Operating Procedures for Aileke Pressure Gauges

Pressure gauges are core pressure instruments used in industrial production and equipment calibration, and their measurement accuracy is crucial for data reliability. Therefore, it is particularly important to carry out standardized calibration, testing, and measurement work. This specification relies on the ALKT511 micro pressure calibration bench and the ALKC400A digital pressure calibrator to conduct fixed-point calibration and verification of stainless steel pressure gauges. The calibration strictly follows environmental standards of 20±2℃ and relative humidity ≤85% RH, completes instrument sealing and docking, and covers full-range testing of positive pressure and vacuum negative pressure. A step-by-step pressure increase and decrease operation is adopted. After stabilizing the pressure at a fixed point, the gauge case is tapped lightly, the indicated value is recorded, and the error is calculated. Throughout the process, metrological operation specifications are strictly adhered to, pressure is controlled smoothly to avoid shocks, and supporting instruments undergo annual verification. Standardized pressure relief and equipment maintenance mechanisms are established to ensure accurate and compliant pressure gauge measurements, providing reliable support for the quality standardization management of industrial equipment.

1. Calibration tool for pressure gauge


The entire verification process must strictly adhere to the current metrological technical specifications, primarily based on JJG52-2013 "Elastic Element Type General Pressure Gauges, Pressure Vacuum Gauges, and Vacuum Gauges". This standard is applicable to the initial verification, subsequent verification, and in-service inspection of elastic element type general pressure gauges, pressure vacuum gauges, and vacuum gauges, covering locally indicating pressure measuring instruments commonly used in industry.

II. Detailed Explanation of Operational Procedures

(I) Preliminary preparations

1. Environmental requirements

The temperature should be controlled at (20±2)℃, with a relative humidity of ≤85%RH, and there should be no condensation. Ensure that the site is free from vibration, dust, and corrosive gases.

2. Tool connection

Connect the standard gauge ALKC400A and the verified pressure gauge Y-100BF in a sealed manner to the ALKT511 output port.

(II) Pressure gauge calibration process

1. Voltage boosting process

First, open the pressure regulating valve of ALKT511, then turn the fine adjustment knob counterclockwise until it stops, and close the pressure relief valve.

• Rotate clockwise for pressure adjustment, increasing the pressure to the verification value of 150kPa. Once the pressure stabilizes and the standard indicated value no longer fluctuates, check the pressure value of the verified pressure gauge. Then, gently tap the side of the verified pressure gauge's casing with your finger (tapping the glass or hitting hard is strictly prohibited), observe the pointer position, and record the indicated value after the tap stabilizes. Use the indicated value after the tap as the actual measured verification reading for this pressure point, and calculate the error.

• For the same operation, rotate clockwise with fine adjustment to apply pressure to the verification points of 300kPa, 450kPa, and 600kPa, check the pressure value of the verified pressure gauge, tap the verified pressure gauge, and record the indicated value after the tap becomes stable.

2. Decompression process

• First, slowly open the pressure relief valve and reduce the pressure to around the verification value. Close the pressure relief valve, and then use fine adjustment to gradually adjust it to the verification point of 450kPa. Once the pressure stabilizes, tap the verified pressure gauge and record the value.

• Perform the same operation with the verification points set to 300kPa and 150kPa, check the pressure value of the verified pressure gauge, tap the verified pressure gauge, and record the indicated value after the tap becomes stable.

3. Pressure relief process

Open the pressure relief valve, gradually release the pressure inside the pipeline, and when the pressure relief reaches 0, the measurement is complete.

(III) Pressure gauge vacuum calibration process

1. Voltage boosting process

First, remove the verified gauge for measuring positive pressure, install the verified gauge for measuring negative pressure, turn the fine adjustment clockwise until it stops, and then close the pressure relief valve.

• Rotate counterclockwise for fine adjustment and apply pressure until reaching the verification value of -25kPa. Once the pressure stabilizes, tap the verified pressure gauge and record the value.

• Perform the same operation with the verification points adjusted to -50kPa, -75kPa, and -100kPa, check the pressure values of the verified pressure gauge, tap the verified pressure gauge, and record the indicated value after the tap becomes stable.

Note:

• When fine-tuning the vacuuming process and the fine adjustment is ineffective, and the verification value is not reached, a second pressurization is required.

• Secondary pressurization steps: First, close the pressure regulating valve, then open the pressure relief valve, and turn the fine adjustment knob clockwise until it stops. Close the pressure relief valve, then open the pressure regulating valve, and use the fine adjustment knob to turn counterclockwise to the verification point.

2. Decompression process

• First, slowly open the pressure relief valve to reduce the pressure to around the verification value, then close the valve. Next, use fine adjustment to gradually adjust the pressure to the verification point of -75kPa. Once the pressure stabilizes, tap the verified pressure gauge and record the value.

• Perform the same operation with the verification points adjusted to -50kPa and -25kPa, check the pressure values of the verified pressure gauge, tap the verified pressure gauge, and record the indicated value after the tap stabilizes.

3. Pressure relief process

Open the pressure relief valve, gradually release the pressure inside the pipeline, and when the pressure relief reaches 0, the measurement is complete.

III. Precautions

Standardized use

• During verification, it is important to ensure that the tolerance of the standard meter is less than that of the verified meter, in order to ensure accurate and reliable verification results that meet the requirements of metrological specifications.

• Operations should follow standard procedures. The ALKT511 micro-pressure calibration station should be pressurized and depressurized slowly to avoid pressure shock.

• Increase the pressure to the verification point and record the indicated value after the standard gauge value stabilizes. For the verified pressure gauge, tap the gauge case gently after the pressure stabilizes, and take the indicated value after tapping as the accurate reading to ensure accurate recording.

• After the inspection is completed, slowly release the pressure to zero and ensure there is no residual pressure before removing the inspected instrument.

Maintenance and calibration cycle

• Regularly conduct metrological verification on the digital pressure calibrator ALKC400A (it is recommended to do so once a year) to ensure that the measurement accuracy meets the standard.

• When the pressure gauge is not in use, the power should be turned off. If it is not used for a long time, it should be charged once every three months.

• If the micro-pressure stage is not in use for a long period, it should be depressurized before storage. A cloth cover should be placed on top to prevent dust from entering the instrument.

IV. Conclusion

The full-range calibration and testing of pressure gauges rely on the Aileco calibration equipment, strictly following standardized metrological procedures to complete the measurement, verification, and data calculation in both positive and negative pressure ranges. The operation strictly controls environmental conditions such as temperature, humidity, and cleanliness, standardizes operations such as instrument sealing and docking, step-wise pressure increase and decrease, stable pressure readings, light tapping for gauge calibration, and error calculation, to avoid pressure shocks and ensure the authenticity and accuracy of data at each verification point. At the same time, it clarifies equipment operation specifications, annual periodic verification, and daily maintenance requirements, and implements this process on a regular basis to ensure that pressure gauge measurement and metrology are compliant and reliable, laying a solid metrological foundation for industrial equipment operation and maintenance as well as quality control.

Related News

Standardised Operating Procedures for the Calibration, Testing and Maintenance of Type K Thermocouples

Standardised Operating Procedures for the Calibration, Testi

How to calibrate a pressure gauge: Operating specifications for full-range calibration of positive pressure and vacuum

How to calibrate a pressure gauge: Operating specifications

Operation procedure and metrological testing specification for calibration of AILEIKE 100MPa high-pressure switch

Operation procedure and metrological testing specification f

A Comprehensive Guide to the Full Process of Calibration, Testing and Measurement of Aileko ALKT511 and ALKC400A Pressure Switches

A Comprehensive Guide to the Full Process of Calibration, Te

A Comprehensive Analysis of the Entire Process for Verifying the Opening and Closing of Pressure Switch Contacts

A Comprehensive Analysis of the Entire Process for Verifying

AILEIKE 100 MPa High-Pressure Switch Calibration Procedure and Metrological Testing Specifications

AILEIKE 100 MPa High-Pressure Switch Calibration Procedure a

Product Categories

  • Pressure series
    • ELECTRODYNAMIC calibration series
    • Pointer pressure gauge
    • Air pressure calibration
    • Hydraulic Calibration
    • Handheld series
    • pressure calibrator
    • Pressure conversion connector
    • Pressure transmitter
  • Digtal pressure gauge
  • Calibration series
    • Temperature calibration
    • 475
  • Liquid level series
    • Radar level gauge
    • guided wave radar
    • Level gauge
    • Tuning fork/RF admittance
    • Magnetic level gauge
  • Temperature series
    • Thermal resistance
    • Bimetal thermometer
    • Thermocouple
  • Flow series
    • Electromagnetic flowmeter
    • Turbine flowmeter
    • Vortex flowmeter
    • Flow meter
    • Ultrasonic flowmeter
  • Petroleum Machinery
  • Display series
    • Digital display series
    • Recording instrument
  • Accessory

Links

Alibaba.comFacebook.comYoutube.comTiktok.comGoogle.comBaidu.com

侧边1

侧边2

Latest Post

  • Standard Calibration and Testing Operating Procedures for Aileke Pressure Gauges
    Standard Calibration and Testing Operati
    2026-11-20
  • Calibration, testing, and standardized operation of industrial pressure gauges with a full range of 0~60MPa
    Calibration, testing, and standardized o
    2026-11-19
  • How to calibrate a pressure gauge: Operating specifications for full-range calibration of positive pressure and vacuum
    How to calibrate a pressure gauge: Opera
    2026-11-18

Feedback

Contact Us

3841141734

+86 18915184475

+86-18915184475

aileike@outlook.com

No. 6, Yinjizhen Industrial Park, Jiangsu Province

Mobile Website

Mobile QR Code


Copyright © 2013-2020 AILEIKE TT&C EQUIPMENT(HUAIAN)CO., LTD. All Rights Reserved.

https://www.youtube.com/@aileike https://x.com/AiLeike1201 https://vk.ru/id1085515017 https://www.youtube.com/@aileike https://www.tiktok.com/@aileike01 +86 18915184475 aileike@outlook.com +86-18915184475
WeChat
WeChat QR Code