aileike@outlook.com +86 18915184475
ENEN PTPT IDID RURU ARAR
Facebook
X
Youtube
TIKTOK
TELEGRAM
AILEIKE TT&C EQUIPMENT(HUAIAN)CO., LTD.
ENEN PTPT IDID RURU ARAR
  • Home
  • About us
  • Products
    • Pressure series
      • ELECTRODYNAMIC calibration series
      • Pointer pressure gauge
      • Air pressure calibration
      • Hydraulic Calibration
      • Handheld series
      • pressure calibrator
      • Pressure conversion connector
      • Pressure transmitter
    • Digtal pressure gauge
    • Calibration series
      • Temperature calibration
      • 475
    • Liquid level series
      • Radar level gauge
      • Level gauge
      • guided wave radar
      • Tuning fork/RF admittance
      • Magnetic level gauge
    • Temperature series
      • Thermal resistance
      • Bimetal thermometer
      • Thermocouple
    • Flow series
      • Electromagnetic flowmeter
      • Turbine flowmeter
      • Vortex flowmeter
      • Flow meter
      • Ultrasonic flowmeter
    • Petroleum Machinery
    • Display series
      • Digital display series
      • Recording instrument
    • Accessory
  • News
    • Technical articles
    • Industry-news
  • F.A.Q
  • Contact us
Get a Quote
Quick Inquiry

Get a Quote

Fill in the form below and we will get back to you shortly.

Technical articles

  1. Home
  2. News
  3. Technical articles
  4. Operating Procedures for the Aileko ALKT...

Operating Procedures for the Aileko ALKT9603 and ALKC400D Calibration Pressure Gauges

Pressure gauges are indispensable measuring instruments in pressure monitoring systems, and their accuracy is a critical safeguard for industrial production. This calibration utilized the Aileko ALKT9603 pneumatic calibration bench in conjunction with the ALKC400D precision digital pressure gauge, to calibrate the Y-100BF dial pressure gauge. Tests were conducted under both positive pressure and vacuum conditions, following the standard procedure of graded pressure increase and stabilization, light tapping to read the value, pressure reduction and re-inspection, and final pressure relief. Calibration data was fully recorded, indication errors were calculated, and operational guidelines and equipment maintenance plans were established to ensure the reliable transmission of pressure measurement values.

I. Pressure Gauge Calibration Tools


The entire verification process must strictly comply with current metrological technical specifications. The primary reference is JJG52-2013, “General Pressure Gauges, Pressure-Vacuum Gauges, and Vacuum Gauges with Elastic Elements,” which applies to the initial verification, periodic verification, and in-service inspections of general pressure gauges, pressure-vacuum gauges, and vacuum gauges with elastic elements, and covers on-site indicating pressure measurement instruments commonly used in industry.

II. Detailed Operational Procedures

(I) Preliminary Preparations

1. Environmental Requirements

Maintain a temperature of (20±2)°C, relative humidity ≤85% RH, and ensure there is no condensation. Ensure the site is free of vibration, dust, and corrosive gases.

2. Connecting Equipment

• Connect the standard gauge ALKC400D and the pressure gauge under test (Y-100BF) to the outlet of the ALKT9603 using a sealed connection.

(II) Pressure Gauge Calibration Procedure

1. Pressurization Process

• First, open the shut-off valve on the ALKT9603. Next, push the positive/negative pressure switch valve inward (do not switch under pressure). Then, turn the fine-tuning knob counterclockwise until it stops, and close the relief valve.

• Use the hand-operated pressure rod to apply pressure until it reaches approximately the calibration point, then use the fine-adjustment knob to slowly turn clockwise to the calibration point of 1 MPa. Once the pressure has stabilized and the standard reading no longer fluctuates, check the pressure reading on the pressure gauge under test. Then, gently tap the side of the pressure gauge’s case with your finger (never tap the glass or tap forcefully), observe the pointer position, and record the reading once it has stabilized after tapping. Use the reading after tapping as the actual calibration reading for that pressure point, and calculate the error.

• Next, use the hand-operated pressure rod to increase the pressure to approximately 1.9 MPa and 2.9 MPa, then stop. Use the fine-tuning knob to slowly adjust the pressure clockwise to the calibration points of 2 MPa and 3 MPa. Once the pressure stabilizes, tap the pressure gauge under test and record the value.

• Before adjusting to the next calibration point, first close the shut-off valve, then use the fine-tuning knob to slowly adjust clockwise to the 4 MPa calibration point. Once the pressure stabilizes, tap the pressure gauge under test and record the reading.

• Finally, use the fine-tuning valve to slowly adjust the pressure clockwise to the test points of 5 MPa and 6 MPa. Once the pressure stabilizes, tap the pressure gauge under test and record the reading.

2. Pressure Relief Process

• First, slowly open the relief valve to reduce the pressure until it reaches the test point, then stop. Close the relief valve and use the fine-tuning valve to slowly adjust the pressure counterclockwise to the test point of 5 MPa. Once the pressure stabilizes, tap the pressure gauge under test and record the reading.

• Repeat the same procedure to adjust to the calibration points of 4 MPa, 3 MPa, 2 MPa, and 1 MPa. Check the pressure reading on the pressure gauge under test, tap the gauge, and record the reading once it stabilizes after tapping.

3. Depressurization Process

Open the relief valve and the shut-off valve in sequence to gradually release the pressure in the pipeline. Once the pressure reaches 0, the measurement is complete.

(III) Vacuum Calibration Process for Pressure Gauges

1. Pressurization Process

• First, remove the pressure gauge under test that measures positive pressure and install the one that measures negative pressure. Pull the positive/negative pressure switch valve outward (do not switch while under pressure). Next, open the shut-off valve, then turn the ALKT9603 fine-tuning knob clockwise until it stops. Close the pressure relief valve.

• Use the hand pump to create a vacuum; stop when the pressure reaches approximately the calibration value. Use the fine-tuning knob to slowly adjust counterclockwise to the calibration point of -0.02 MPa. Once the pressure stabilizes, tap the pressure gauge under test and record the reading.

• Repeat the same procedure to adjust to the calibration points of -0.04 MPa, -0.06 MPa, -0.08 MPa, and -0.095 MPa. Check the pressure reading on the pressure gauge under test, tap the gauge, and record the reading once it stabilizes after the tap.

2. Pressure Reduction Process

• First, slowly open the relief valve to reduce the pressure to approximately the calibration value, then stop. Close the relief valve and use the fine-adjustment valve to slowly turn clockwise until the pressure reaches the calibration point of -0.08 MPa. Once the pressure stabilizes, tap the pressure gauge under test and record the reading.

• Repeat the same procedure to adjust to the calibration points of -0.06 MPa, -0.04 MPa, and -0.02 MPa. Observe the pressure reading on the pressure gauge under test, tap the gauge, and record the reading once it has stabilized.

3. Pressure Relief Process

Open the relief valve to gradually release the pressure in the pipeline. Once the pressure is reduced to 0, the measurement is complete.

III. Precautions

Proper Use

• Follow standard operating procedures. When pressurizing or depressurizing the ALKT9603 pressure calibration stand, do so slowly to avoid pressure surges.

• Pressurize to the calibration point, and record the reading once the standard gauge’s value has stabilized. For the pressure gauge under test, gently tap the case after the pressure has stabilized; use the reading immediately after tapping as the final value to ensure accurate recording.

• Upon completion of the test, slowly depressurize the system to zero and ensure there is no residual pressure before removing the pressure gauge under test.

Maintenance and Calibration Schedule

• Perform periodic metrological verification on the ALKC400D precision digital pressure gauge (recommended once a year) to ensure measurement accuracy meets standards.

• When the pressure gauge is not in use, turn off the power; if it will not be used for an extended period, recharge it once every three months.

• If the pressure test bench is not used for an extended period, depressurize it before storage and cover it with a cloth cover to prevent dust from entering the instrument.

IV. Conclusion

This paper describes the full-range standardized calibration and testing of positive pressure and vacuum dial pressure gauges. It strictly controls environmental conditions such as temperature and humidity during the testing process and standardizes core operations including pressure switching, pressure rise and fall rates, and tapping to read values. Raw data is recorded, indication errors are calculated, and the instrument’s metrological performance is comprehensively evaluated. It clarifies the operating procedures for calibration equipment, periodic verification, and the requirements for daily maintenance and storage of instruments. Regular pressure gauge calibration is implemented to ensure the stability of measurement performance.

Related News

Operating Instructions and Applications for the AILEIKE ALKB9602 Portable Air Pump

Operating Instructions and Applications for the AILEIKE ALKB

Practical Technical Guidelines for the Calibration, Inspection, and Measurement of Marine Pressure Gauges Using AILEIKE Handheld Hydraulic Pumps

Practical Technical Guidelines for the Calibration, Inspecti

A Comprehensive Guide to the Full Process of Calibration, Testing and Measurement of Aileko ALKT511 and ALKC400A Pressure Switches

A Comprehensive Guide to the Full Process of Calibration, Te

How to select the model of Thermotechnical Treasure (Thermotechnical Multi-function Calibrator) and HART Handheld Communicator for on-site use

How to select the model of Thermotechnical Treasure (Thermot

Introduction to the Operating Specifications and Usage Scenarios of the AILEIKE ALKT803 Hydraulic Calibration Bench

Introduction to the Operating Specifications and Usage Scena

Barometric instrument calibration equipment | Operation and application of the ALKT9603 barometric calibration bench by AILEIKE

Barometric instrument calibration equipment | Operation and

Product Categories

  • Pressure series
    • ELECTRODYNAMIC calibration series
    • Pointer pressure gauge
    • Air pressure calibration
    • Hydraulic Calibration
    • Handheld series
    • pressure calibrator
    • Pressure conversion connector
    • Pressure transmitter
  • Digtal pressure gauge
  • Calibration series
    • Temperature calibration
    • 475
  • Liquid level series
    • Radar level gauge
    • guided wave radar
    • Level gauge
    • Tuning fork/RF admittance
    • Magnetic level gauge
  • Temperature series
    • Thermal resistance
    • Bimetal thermometer
    • Thermocouple
  • Flow series
    • Electromagnetic flowmeter
    • Turbine flowmeter
    • Vortex flowmeter
    • Flow meter
    • Ultrasonic flowmeter
  • Petroleum Machinery
  • Display series
    • Digital display series
    • Recording instrument
  • Accessory

Links

Alibaba.comFacebook.comYoutube.comTiktok.comGoogle.comBaidu.com

侧边1

侧边2

Latest Post

  • Operating Procedures for the Aileko ALKT9603 and ALKC400D Calibration Pressure Gauges
    Operating Procedures for the Aileko ALKT
    2026-11-09
  • Operating Procedures for Calibrating Marine Pressure Gauges on Vessels Using the AILEIKE 103SF and ALKC400D
    Operating Procedures for Calibrating Mar
    2026-11-07
  • Guide for Standardized Calibration and Precise Detection and Measurement of Stainless Steel Pressure Gauges
    Guide for Standardized Calibration and P
    2026-11-06

Feedback

Contact Us

3841141734

+86 18915184475

+86-18915184475

aileike@outlook.com

No. 6, Yinjizhen Industrial Park, Jiangsu Province

Mobile Website

Mobile QR Code


Copyright © 2013-2020 AILEIKE TT&C EQUIPMENT(HUAIAN)CO., LTD. All Rights Reserved.

https://www.youtube.com/@aileike https://x.com/AiLeike1201 https://vk.ru/id1085515017 https://www.youtube.com/@aileike https://www.tiktok.com/@aileike01 +86 18915184475 aileike@outlook.com +86-18915184475
WeChat
WeChat QR Code