aileike@outlook.com +86 18915184475
ENEN PTPT IDID RURU ARAR
Facebook
X
Youtube
TIKTOK
TELEGRAM
AILEIKE TT&C EQUIPMENT(HUAIAN)CO., LTD.
ENEN PTPT IDID RURU ARAR
  • Home
  • About us
  • Products
    • Pressure series
      • ELECTRODYNAMIC calibration series
      • Pointer pressure gauge
      • Air pressure calibration
      • Hydraulic Calibration
      • Handheld series
      • pressure calibrator
      • Pressure conversion connector
      • Pressure transmitter
    • Digtal pressure gauge
    • Calibration series
      • Temperature calibration
      • 475
    • Liquid level series
      • Radar level gauge
      • Level gauge
      • guided wave radar
      • Tuning fork/RF admittance
      • Magnetic level gauge
    • Temperature series
      • Thermal resistance
      • Bimetal thermometer
      • Thermocouple
    • Flow series
      • Electromagnetic flowmeter
      • Turbine flowmeter
      • Vortex flowmeter
      • Flow meter
      • Ultrasonic flowmeter
    • Petroleum Machinery
    • Display series
      • Digital display series
      • Recording instrument
    • Accessory
  • News
    • Technical articles
    • Industry-news
  • F.A.Q
  • Contact us
Get a Quote
Quick Inquiry

Get a Quote

Fill in the form below and we will get back to you shortly.

Technical articles

  1. Home
  2. News
  3. Technical articles
  4. Calibration and standardized operation o...

Calibration and standardized operation of industrial pressure gauge with full range of 0~60MPa

The pressure gauge is a crucial pressure measuring instrument in industrial production and automation control systems. Its measurement accuracy is crucial to the stability of process operation, necessitating regular standardized verification and testing. This calibration was conducted strictly in accordance with metrological technical specifications, utilizing the ALKT803 hydraulic calibration bench and ALKC400A digital pressure calibrator to verify the Y-100BF pressure gauge. Throughout the calibration process, environmental temperature and humidity were strictly controlled, and preparatory work such as equipment fluid injection, exhaust, and pipeline connection was completed in advance. The calibration involved multi-point pressure increase and decrease testing across the full range, adhering to the standardized requirements of slow pressure adjustment, gentle tapping on the gauge case, and stable readings. The instrument's indication error and return difference were precisely calculated. Through this calibration, instrument measurement deviations were identified and resolved, ensuring the reliability of pressure gauge measurement data.

1. Calibration tool for pressure gauge


The entire verification process must strictly adhere to the current metrological technical specifications, primarily based on JJG52-2013 "General Pressure Gauges, Pressure Vacuum Gauges, and Vacuum Gauges with Elastic Elements". This standard is applicable to the initial verification, subsequent verification, and in-service inspection of general pressure gauges, pressure vacuum gauges, and vacuum gauges with elastic elements, covering locally indicating pressure measuring instruments commonly used in industry.

II. Detailed Explanation of Operational Procedures

(I) Preliminary preparations

1. Environmental requirements

The temperature should be controlled at (20±2)℃, with a relative humidity of ≤85%RH, and there should be no condensation. Ensure that the site is free from vibration, dust, and corrosive gases.

2. Hydraulic platform liquid injection, pressurization, conduction, and tool connection

• Prepare the pressure transmission medium (pure water or calibration oil).

First, unscrew the pressure relief valve of the ALKT803 hydraulic calibration bench, inject the medium into the liquid storage cup, and ensure that enough medium (no less than two-thirds) is injected. After the injection is complete, reinstall and tighten the pressure relief valve.

• Next, discharge the excess gas from the hydraulic platform. First, unscrew the plugs of the three output ports, open the pressure regulating valve, pressure relief valve, and overpressure cutoff valve, adjust the fine adjustment valve counterclockwise to the appropriate position, and close the pressure relief valve. Then, use a lever to apply pressure, allowing the pilot pressure to reach the three output ports. After the excess gas is discharged, seal and connect the standard gauge ALKC400A and the verified pressure gauge Y-100BF to the ALKT803 output port.

(II) Pressure gauge calibration process

1. Voltage boosting process

• Use the ALKT803 lever to apply pressure, stopping when the pressure reaches above 5MPa. Close the pressure regulating valve and the overpressure cutoff valve, then use fine adjustment to increase the pressure clockwise to the verification point of 10MPa. After the pressure stabilizes and the standard indicated value no longer fluctuates, check the pressure value of the verified pressure gauge. Then, gently tap the side of the verified pressure gauge's casing with your finger (do not tap the glass or tap hard), observe the position of the pointer, and record the indicated value after the tap stabilizes. Use the indicated value after the tap as the actual measured verification reading for this pressure point, and calculate the error.

• Use the trim valve to adjust clockwise to a pressure value of 20MPa. Once the pressure stabilizes, tap the pressure gauge being tested and record the value.

• For the same operation, use the trim valve to increase the pressure clockwise to pressure values of 30MPa, 40MPa, 50MPa, and 60MPa, check the pressure values on the pressure gauge, and gently tap the verified pressure gauge. Record the indicated value after the tap is stabilized.

2. Decompression process

• Directly use the fine adjustment to decrease the pressure counterclockwise, with pressure values of 50MPa, 40MPa, 30MPa, 20MPa, and 10MPa. Check the pressure values on the pressure gauge, and gently tap the verified pressure gauge. Record the indicated value after the tap stabilizes.

3. Pressure relief process

Open the pressure relief valve, pressure regulating valve, and overpressure cutoff valve in sequence, set the pressure relief to 0, and the measurement is complete.

III. Precautions

Standardized use

• During verification, it is important to ensure that the tolerance of the standard instrument is less than that of the instrument being verified, to ensure accurate and reliable verification results that meet the metrological specifications.

• The pressure transmitting medium should be clean and free of impurities to prevent blockage of pipelines, damage to the hydraulic platform, and pressure gauge.

• Operations should follow standard procedures. The ALKT803 hydraulic calibration bench should be pressurized and depressurized slowly to avoid pressure shock.

• Increase the pressure to the verification point and record the indicated value after the standard gauge value stabilizes. For the verified pressure gauge, gently tap the gauge case after the pressure stabilizes, and take the indicated value after tapping as the accurate reading to ensure accurate recording.

• After the inspection is completed, slowly release the pressure to zero and ensure there is no residual pressure before removing the instrument being inspected.

Maintenance and calibration cycle

• Regularly conduct metrological verification on the digital pressure calibrator ALKC400A (it is recommended to do so once a year) to ensure that the measurement accuracy meets the standard.

• When the pressure gauge is not in use, the power should be turned off. If it is not used for a long time, it should be charged once every three months.

• If the hydraulic bench is not to be used for an extended period, it needs to be depressurized before storage. Pour out the liquid in the reservoir cup and cover it with a cloth cover to prevent dust from entering the instrument.

IV. Conclusion

The full-range calibration of pressure gauges has been completed, strictly adhering to the metrological procedures throughout the entire operation process. The testing covered all key measuring points ranging from 10MPa to 60MPa, accurately calculating the indication error and return error through pressure rise and fall tests and steady-state readings. During the operation, the details of the control and management were standardized, effectively avoiding issues such as pressure shock, medium impurities, and reading deviations, fully verifying the operational performance of the tested gauge and the supporting calibration equipment. Accurate metrology cannot be achieved without long-term management. In the future, we will strictly implement the periodic verification system, conduct daily maintenance of instruments, and continuously ensure the accuracy and reliability of pressure measurement data, providing a solid guarantee for the stable operation and production of industrial equipment.

Related News

AILEIKE ALKC400T Precision Digital Pressure Gauge: Operating Instructions and Application Scenarios

AILEIKE ALKC400T Precision Digital Pressure Gauge: Operating

Multi-Point Metrological Testing of Pressure Transmitters Using a Box-Type Electric Pressure Calibration Bench

Multi-Point Metrological Testing of Pressure Transmitters Us

Operation method and application scenarios of the ALKT803 hydraulic calibration bench

Operation method and application scenarios of the ALKT803 hy

Introduction to the Operating Specifications and Usage Scenarios of the AILEIKE ALKT803 Hydraulic Calibration Bench

Introduction to the Operating Specifications and Usage Scena

Operating Procedures for the Aileko ALKT9603 and ALKC400D Calibration Pressure Gauges

Operating Procedures for the Aileko ALKT9603 and ALKC400D Ca

Operation explanation of AILEIKE portable air pump ALKB602, pressure gauge calibration is no longer a hassle

Operation explanation of AILEIKE portable air pump ALKB602,

Product Categories

  • Pressure series
    • ELECTRODYNAMIC calibration series
    • Pointer pressure gauge
    • Air pressure calibration
    • Hydraulic Calibration
    • Handheld series
    • pressure calibrator
    • Pressure conversion connector
    • Pressure transmitter
  • Digtal pressure gauge
  • Calibration series
    • Temperature calibration
    • 475
  • Liquid level series
    • Radar level gauge
    • guided wave radar
    • Level gauge
    • Tuning fork/RF admittance
    • Magnetic level gauge
  • Temperature series
    • Thermal resistance
    • Bimetal thermometer
    • Thermocouple
  • Flow series
    • Electromagnetic flowmeter
    • Turbine flowmeter
    • Vortex flowmeter
    • Flow meter
    • Ultrasonic flowmeter
  • Petroleum Machinery
  • Display series
    • Digital display series
    • Recording instrument
  • Accessory

Links

Alibaba.comFacebook.comYoutube.comTiktok.comGoogle.comBaidu.com

侧边1

侧边2

Latest Post

  • Calibration and standardized operation of industrial pressure gauge with full range of 0~60MPa
    Calibration and standardized operation o
    2026-11-10
  • Operating Procedures for the Aileko ALKT9603 and ALKC400D Calibration Pressure Gauges
    Operating Procedures for the Aileko ALKT
    2026-11-09
  • Operating Procedures for Calibrating Marine Pressure Gauges on Vessels Using the AILEIKE 103SF and ALKC400D
    Operating Procedures for Calibrating Mar
    2026-11-07

Feedback

Contact Us

3841141734

+86 18915184475

+86-18915184475

aileike@outlook.com

No. 6, Yinjizhen Industrial Park, Jiangsu Province

Mobile Website

Mobile QR Code


Copyright © 2013-2020 AILEIKE TT&C EQUIPMENT(HUAIAN)CO., LTD. All Rights Reserved.

https://www.youtube.com/@aileike https://x.com/AiLeike1201 https://vk.ru/id1085515017 https://www.youtube.com/@aileike https://www.tiktok.com/@aileike01 +86 18915184475 aileike@outlook.com +86-18915184475
WeChat
WeChat QR Code